# Introduction he maxilla articulates with nine other bones: the frontal cranial and the ethmoid, as well as the "nasal, zygomatic, lacrimal, inferior nasal concha, palatine, vomer, and the adjacent fused maxilla." It is connected to other bones above through sutures. (Figure 1). In growing children, the maxilla departs from circummaxillary sutures when face mask treatment is applied (1). Face masks, also called reverse-pull headgear, have been used throughout much of history to move the maxilla both forwards and downwards in patients with midfacial deficiencies (2). Figure 2 depicts the clinical application of a face mask. # Figure 2: Clinical application of a face mask The best treatment timing for growing patients is still controversial, and the correlation between cooperation and age is one of the most confounding variables. (3)(4)(5) The recommended wearing time of a face mask is usually longer than 14 hours in a day (6) (7), but this is entirely dependent on the cooperation of the patient. Studies report that received compliance is insufficient (8) (9). A previous study suggested measuring wear time using TheraMon chip technology, which used sensors that collected time and temperature data. It was placed on the forehead of the patient. (10) However, to our knowledge, no attempt has been made to measure the force applied against the full reverse headgear in real-time. Since the suggested force for face masks lies around 300 to 400 grams, keeping this pressure consistent, especially during sleep, is a challenge. To overcome the complications in this process, we used IoT technology and transferred the collected data onto their phone in real-time to use as an asset. This data could be used to create an entirely This sensor used rubber bands to detect the weight applied to the face mask. # Materials and Method # Arduino Force Sensor Circuit This force sensor converted the code from the sensor into units (grams). # MIT App Inventor The face mask patient would run an app to connect their phone to this Bluetooth circuit, which was coded (Figure 4) and designed using MIT App Inventor. When a subject presses a 'scan' button, it will send data to the phone. (Figure 5) # Arduino Bluetooth Circuit This connects the Arduino force sensor to the Bluetooth network, connecting the sensors and the patient's phone. This required coding to detect when the data should be sent, i.e., when the LED was turned on, signifying that the Bluetooth signal was functioning. # Google Firebase This database sent data from Arduino Bluetooth so that it could be accessed by people other than the patient, making the system functional. (Figure 6)There was also a private cloud generation process necessary to prepare it.Once data is transported from the phone to Google Firebase, the database offers it to both the patient and the orthodontist. # Results Utilizing face masks and IoT technology, we were able to detect whether and how much weight (0 to 1000 grams) was being applied to a face mask in realtime with an interval of thirty seconds. (Figure 7). # Discussion Orthodontists always strive to apply the optimal force to their patient's orthodontic devices. However, due to the amount of patient cooperation necessary to conduct their practice successfully, keeping track of how much force is being applied at home and outside of the clinic seems impossible. The advent of IoT technology could potentially solve his problems. It opens comprehensive treatment care for both doctors and patients (Figure 3). When the patients wear the facemask attached to the sensor, Bluetooth will transfer the amount of force to their cell phones. The data is real-time based, and the patient can identify the force level, which is also shown graphically in the background (Figure 4). Further warning messages or beeps will be incorporated when the patients use weak or loosened elastics or insufficient wearing time is noted. Our results were able to detect and digitalize how much weight was being applied, as well as the patient's cooperation. Such data collected will enable far more concise feedback for patients in the future. Besides, the accumulated results will be able to reveal efficient wearing time and force for individual patients, rather than just longer than 12 hours a day. Therefore, doctors can instruct individualized optimum force and wearing time based on scientific evidence with confidence. V. # Conclusion We suggested an IoT based tractable system for a facemask. This workflow can be widely applicable to any removable appliances in the future. Collected data will provide a comprehensive understanding of optimal force and timing for the treatment. 1![Figure 1: A depiction of circummaxillary sutures](image-2.png "Figure 1 :") 3![Figure 3: Demonstrates the role of each component and the feature of combination.1. Load Cell Weight Sensor (AD Module ESU)This sensor used rubber bands to detect the weight applied to the face mask.](image-3.png "Figure 3 :") 4![Figure 4: Code used to transfer data from the Arduino to the phone via Bluetooth](image-4.png "Figure 4 :") 6![Figure 6: Code used to send data from Arduino to Google Firebase](image-5.png "Figure 6 :") 7![Figure 7: Chart of real-time measured pressure IV.](image-6.png "Figure 7 :") ![](image-7.png "") ![](image-8.png "") * Skeletal effects of early treatment of Class III malocclusion with maxillary expansion and facemask therapy TBaccetti JSMcgill LFranchi JAMcnamaraJr Tollaroijajoo DOrthopedics 1998 113 * Cephalometric effects of combined palatal expansion and facemask therapy on Class III malocclusion PENartallo-Turley TurleyPkjtao 1998 68 * Skeletal changes of maxillary protraction in patients exhibiting skeletal class III malocclusion: a comparison of three skeletal maturation groups K-SCha The Angle Orthodontist 73 1 2003 * Cephalometric effects of face mask/expansion therapy in Class III children: a comparison of three age groups AJKapust PMSinclair PKTurley * American Journal of Orthodontics and Dentofacial Orthopedics 113 2 1998 * Assessment of skeletal and dental changes by maxillary protraction SJSung HSBaik American Journal of Orthodontics and Dentofacial Orthopedics 114 5 1998 * Effectiveness of maxillary protraction using a hybrid hyrax-facemask combination: a controlled clinical study MNienkemper BWilmes LFranchi DDrescher The Angle Orthodontist 85 5 2015 * Short-term effects of a modified A lt-RAMEC protocol for early treatment of Class III malocclusion: a controlled study CMasucci LFranchi VGiuntini EDefraia Orthodontics & craniofacial research 17 4 2014 * Questionnaire study of electronic wear-time tracking as experienced by patients and parents during treatment with removable orthodontic appliances TCSchott SSchrey JWalter BAGlasl BLudwig Journal of Orofacial Orthopedics/Fortschritte der Kieferorthopädie 74 3 2013 * Objective assessment of patient compliance with removable orthodontic appliances: a cross-sectional cohort study GTsomos BLudwig JGrossen PPazera NGkantidis The Angle Orthodontist 84 1 2014 * Wear-time recording during early class III facemask treatment using TheraMon chip technology BStocker JHWillmann BWilmes SVasudavan DDrescher American Journal of Orthodontics and Dentofacial Orthopedics 150 3 2016