The Flat Panel Volumetric Computed Tomography in in Vivo Tissue Engineering of Bone: Possibilities and Limitations
Keywords:
Abstract
The scaffold-based tissue engineering of bones is an extremely promising concept with regard to the regeneration of major bone defects due to trauma, tumour or developmental abnormalities as well as for the treatment of pseudo-arthroses. The in vivo testing of implants is a significant phase in the development of specimens for the clinical application of suitable scaffolds. The collection of an optimal amount of information from these initial - clinical - tests demands, ideally, the most diagnostically conclusive studies possible. We tested the procedure of flat panel volumetric computer tomography (fpvCT) thus far virtually untried in the area of bone tissue engineering for the in vivo evaluation of small animal experiments and compared it with other methods (projection radiography, micro-CT, histology). The main questions were whether in situ osteosynthesis decreased representability (artefact formation), the scaffold could be demonstrated by means of fpvCT, and whether the course of degradation and bone growth could be observed, the course of growth precisely evaluated, neoformation of vessels demonstrated in the osteotomic cleft, and what conclusions could be reached with regard to animal models and osteosynthesis. We worked with a CT from the company GE Global Research, Niskayuna, New York. This flat panel volumetric computed tomograph functions with two flat panel radiographic sensors with a resolution of 1024×1024 pixels in each instance. We were able to demonstrate that the fpvCT is an alternative to be considered seriously in terms of the in vivo evaluation of small animal experiments on behalf of scaffold- based tissue engineering. It is superior to projection radiography and can replace the micro-CT, if high resolution is not required. Major advantages of this method over the micro- CT are the shorter scan time, the lower radiation exposure, the larger presentable area and the possibility of carrying out several experiments on a single animal over the course of time. In terms of resolution the fpvCT is superior to the micro- CT. Above all with respect to issues concerning the neoformation of bone and the differentiation between degraded scaffold and new bone, histology is indispensable.
Downloads
- Article PDF
- TEI XML Kaleidoscope (download in zip)* (Beta by AI)
- Lens* NISO JATS XML (Beta by AI)
- HTML Kaleidoscope* (Beta by AI)
- DBK XML Kaleidoscope (download in zip)* (Beta by AI)
- LaTeX pdf Kaleidoscope* (Beta by AI)
- EPUB Kaleidoscope* (Beta by AI)
- MD Kaleidoscope* (Beta by AI)
- FO Kaleidoscope* (Beta by AI)
- BIB Kaleidoscope* (Beta by AI)
- LaTeX Kaleidoscope* (Beta by AI)
How to Cite
References
O. Jeffrey, James Hollinger, Kleinschmidt (1990) The Critical Size Defect as an Experimental Model To Test Bone Repair Materials. 1, 60-68.
L. L, Goyenvalle E, Aguado E, Hochmand-Cuny M, Enkel B, Pilet P, Daculsi G, Layrolle P (2005) Small-animal models for testing macroporous ceramic bone substitutes. 72(1), 69-78. https://doi.org/10.1002/jbm.b.30118
Babis CG, Soucacos PN (2005) Bone Scaffolds: The Role of Mechanical Stability and Instrumentation. (Suppl 4), 34-44.
Obert M, Ahlemeyer B, Baumgart-Vogt E, Traupe H (2005) Flat-Panel Volumetric Computed Tomography A New Method for Visualizing Fine Bone Detail in Living Mice. 4, 560-565.
Jeffrey Fialkov, Chantal Holy, Molly Shoichet, John Davies (2003) In vivo bone engineering in a rabbit femur J Craniofac Surg. 14(3), 324-332. https://doi.org/10.1097/00001665-200305000-00010
Heidrun Schaaf, Philipp Streckbein, Martin Obert, Birgit Goertz, Petros Christophis, Hans-Peter Howaldt, Horst Traupe (2008) High resolution imaging of craniofacial bone specimens by flat-panel volumetric computed tomography J Cranio-Maxillofac Surg. 36(4), 234-238. https://doi.org/10.1016/j.jcms.2008.02.006
Kiessling F, Greschus S, Lichy MP, Block C, Vosseleer S, Moll J, Mueller MM, Fusenig NE, Traupe H, Semmler W (2004) Volumetric computed tomography (VCT): a new technology for noninvasive, high-resolution monitoring of tumor angiogenesis Nature Medicine. 10, 1133-1136.
Susanne Greschus, Fabian Kiessling, Matthias Lichy, Jens Moll, Margareta Mueller, Rajkumar Savai, Frank Rose, Clemens Ruppert, Andreas Günther, Marcus Luecke, Norbert Fusenig, Wolfhard Semmler, Horst Traupe (2005) Potential Applications of Flat-Panel Volumetric CT in Morphologic, Functional Small Animal Imaging. 7(8), 730-740. https://doi.org/10.1593/neo.05160
Christian Weinand, Rajiv Gupta, Eli Weinberg, Ijad Madisch, Craig Neville, Jesse Jupiter, Joseph Vacanti (2009) Toward Regenerating a Human Thumb In Situ Tissue Eng Part A. 15(9), 2605-2615. https://doi.org/10.1089/ten.tea.2008.0467
Obenhauer S, Dullin C, Alves F, Missbach-Guenther J, Grabbe E, Heuser M (2007) Flat-panel-detector-based volumetric CT: performance evaluation of imaging for skeletal structures of small animals in comparison to multislice CT Clin Imaging. 31(1), 18-22. https://doi.org/10.1016/j.clinimag.2006.09.029
Reichardt B, Sarwar A, Bartling SH, Cheung A, Grasruck M, Leidecker C, Bredalla MA, Brady TJ, Gupa R (2008) Musculoskeletal Applications of flat-panel volume CT Skelet Radiol. 37(12), 1069-1076. https://doi.org/10.1007/s00256-008-0473-0
Published
2015-03-02
Issue
Section
License
Copyright (c) 2015 Authors and Global Journals Private Limited

This work is licensed under a Creative Commons Attribution 4.0 International License.