Determination of the Compound Biological Effectiveness (CBE) Factors based on the ISHIYAMA-IMAHORI Deterministic Parsing Model with the Dynamic PET Technique

Authors

  • Shintaro Ishiyama

Keywords:

boron neutron capture therapy, compound biological effectiveness, borono-phenylalanine, tumor, 10B(n, #x3B1;)7 li, sigmoid function

Abstract

Abstract not found

How to Cite

Determination of the Compound Biological Effectiveness (CBE) Factors based on the ISHIYAMA-IMAHORI Deterministic Parsing Model with the Dynamic PET Technique. (2015). Global Journal of Medical Research, 15(F4), 1-5. https://medicalresearchjournal.org/index.php/GJMR/article/view/991

References

B Bayanov, V Belov, V Kindyuk, E Oparin, S Taskaev (2004) Lithium neutron producting target for BINP accelerator-based neutron source. 61, 817-821.

C Willis, J Lenz, D Swenson (2008) High-power lithium target for accelerator-based BNCT. 08, 223-225.

S Halfon, M Paul, A Arenshtam, D Berkovits, M Bisyakoev, I Eliyahu, G Feinberg, N Hazenshprung, D Kijel, A Nagler, I Silverman High power accelerator-based boron neutron capture with a liquid lithium target and new These values of N th , N max and N th /N max for normal tissue and tumor are listed in the table (Table 2). From these results, The CBE factors for normal tissue and tumor in a brain tumor patient were calculated by eq. (2) and these results are given in the table 3 (Table 3).

Jingli Kiger, W Kiger, Kent Riley, Peter Binns, Hemant Patel, John Hopewell, Otto Harling, Paul Busse, Jeffrey Coderre (2008) Functional and Histological Changes in Rat Lung after Boron Neutron Capture Therapy. 170(1), 60-69.

Minoru Suzuki, Shin‐ichiro Masunaga, Yuko Kinashi, Masao Takagaki, Yoshinori Sakurai, Toru Kobayashi, Koji Ono (2000) The Effects of Boron Neutron Capture Therapy on Liver Tumors and Normal Hepatocytes in Mice. 91(10), 1058-1064.

G Morris, Dr, H Smith, Et Patel, Al (2000) Boron microlocalization in oral mucosal tissue. 82(11), 1764-1771.

Shintaro Ishiyama, Y Imahori (2014) Deterministic Parsing Model of the Compound Biological Effectiveness (CBE) Factor for Intracellular 10Boron Distribution in Boron Neutron Capture Therapy. 05(14), 1388-1398.

Shintaro Ishiyama (2014) Deterministic Parsing Model of the Compound Biological Effectiveness (CBE) Factor for Intracellular 10Boron Distribution in Boron Neutron Capture Therapy. 05(14), 1388-1398.

Y Imahori, S Ueda, Y Ohmori (1998) Fluorine-18-labeled fluoroboronophenylalanine PET in Patients with Glioma. 39(2), 325-333.

Y Imahori (1998) Positron emission tomographybased boron neutron capture therapy using boronophenylalanine for high-grade gliomas: part II. 4(8), 1833-1841.

Determination of the Compound Biological Effectiveness (CBE) Factors based on the ISHIYAMA-IMAHORI Deterministic Parsing Model with the Dynamic PET Technique

Published

2015-11-02

How to Cite

Determination of the Compound Biological Effectiveness (CBE) Factors based on the ISHIYAMA-IMAHORI Deterministic Parsing Model with the Dynamic PET Technique. (2015). Global Journal of Medical Research, 15(F4), 1-5. https://medicalresearchjournal.org/index.php/GJMR/article/view/991