Comparitive Evaluation of Novel Desensitising Agents on Dentinal Tubule Occlusion-A Scanning Electron Microscopic Study

Authors

  • Dr. Madhavi Ajit Shetty

  • Dr. Sharad Kokate

  • Dr. Vibha Hegde

Keywords:

dentinal hypersensitivity; novamin; gluma; diode laser, pro-arginine; scanning electron microscope

Abstract

Abstract not found

How to Cite

Comparitive Evaluation of Novel Desensitising Agents on Dentinal Tubule Occlusion-A Scanning Electron Microscopic Study. (2020). Global Journal of Medical Research, 20(J5), 11-16. https://medicalresearchjournal.org/index.php/GJMR/article/view/101397

References

N Kumar, D Mehta (2005) Short-term assessment of the Nd: YAG laser with and without sodium fluoride varnish in the treatment of dentin hypersensitivity-A clinical and scanning electron microscopy study. 76(7), 1140-1147.

E Absi, M Addy, D Adams (1987) Dentine hypersensitivity. 14(5), 280-284.

A Gaffar (1999) Treating hypersensitivity with fluoride varnish Compendium of Continuing Education in. 20(1), 27-33.

M Brannstrom (1966) Sensitivity of dentine. 21(4), 517-526.

T Ling, D Gillam (1996) The effectiveness of desensitizing agents for the treatment of cervical dentin sensitivity (CDS)-A review. 44(1), 5-12.

Peter Jacobsen, Gretchen Bruce (2001) Clinical Dentin Hypersensitivity: Understanding the Causes and Prescribing a Treatment. 2(1), 27-34.

A Moritz, U Schoop, K Goharkhay (1998) Longterm effects of CO2 laser irradiation on the treatment of hypersensitive dental necks: results of an in vivo study. 16(4), 211-215.

A Moritz, N Gutknecht, U Schoop, K Goharkhay, Danila Ebrahim, J Wernisch, W Sperr (1996) The Advantage of CO 2 -Treated Dental Necks, in Comparison with a Standard Method: Results of an in Vivo Study. 14(1), 27-32.

Chengfei Zhang, Koukichi Matsumoto, Yuichi Kimura, Tomomi Harashima, Frank Takeda, Hui Zhou (1998) Effects of CO2 laser in treatment of cervical dentinal hypersensitivity. 24(9), 595-597.

F Schwarz, N Arweiler, T Georg, E Reich (2002) Desensitizing effects of an Er: YAG laser on hypersensitive dentine: a controlled, prospective clinical study. 29(3), 211-215.

H Watanabe, K Kataoka, H Iwami, T Shinoki, Y Okagami, I Ishikawa (2003) In vitro and in vivo studies on application of erbium: YAG laser for dentine hypersensitivity. 1248, 455-457.

Alberto Sicilia, Susana Cuesta‐frechoso, Alfonso Suárez, Jorge Angulo, Armando Pordomingo, Pablo De Juan (2009) Immediate efficacy of diode laser application in the treatment of dentine hypersensitivity in periodontal maintenance patients: a randomized clinical trial. 36(8), 650-660.

R Orchardson (2000) Strategies for the management of dentine hypersensitivity. 315-325.

L Litkowski (1998) Pilot clinical and in vitro studies evaluating NovaMin in desensitizing dentifrices. 77, 199.

Mythri Halappa, Prasun Roy, J Bharateesh, K Kashinath (2015) Pro-Argin: A promising technology for dental hypersensitivity. 5(2), 68.

J Rees, M Addy (2002) A cross‐sectional study of dentine hypersensitivity. 29(11), 997-1003.

M Yoshiyama, J Masada, A Uchida, H Ishida (1989) Scanning Electron Microscopic Characterization of Sensitive vs. Insensitive Human Radicular Dentin. 68(11), 1498-1502.

M Narhi (2000) Responses of pulpal nociceptors to tissue injury and inflammation. 257-266.

M Morris, R Davis, B Richardson (1999) Clinical efficacy of two dentin desensitizing agents. 12, 72-76.

D Gillam, N Mordan, A Sinodinou, J Tang, J Knowles, I Gibson (2001) The effects of oxalate-containing products on the exposed dentine surface: an SEM investigation. 28(11), 1037-1044.

L Gangarosa (1994) Current strategies for dentistapplied treatment in the management of hypersensitive dentine. 39(1), 101-S106.

David Kerns, Michael Scheidt, David Pashley, Jack Horner, Scott Strong, Thomas Van Dyke (1991) Dentinal Tubule Occlusion and Root Hypersensitivity. 62(7), 421-428.

R Ikemura (1993) Studies on new treatment agents for dentin hypersensitivity. 36, 1686-1698.

T Wichgers, R Emert (1996) Dentin hypersensitivity. 44(3), 225-232.

A Moritz, U Schoop, K Goharkhay, M Aoid, P Reichenbach, M Lothaller, J Wernisch, W Sperr (1998) Long-Term Effects of CO 2 Laser Irradiation on Treatment of Hypersensitive Dental Necks: Results of an in Vivo Study. 16(4), 211-215.

N Kumar, D Mehta (2005) Short‐Term Assessment of the Nd:YAG Laser With and Without Sodium Fluoride Varnish in the Treatment of Dentin Hypersensitivity - A Clinical and Scanning Electron Microscopy Study. 76(7), 1140-1147.

W Lan, H Liu, C Lin (1999) The combined occluding effect of sodium fluoride varnish and Nd: YAG laser irradiation on human dentinal tubules. 25(6), 424-426.

Snezana Pesevska, Marija Nakova, Kiro Ivanovski, Nikola Angelov, Ljiljana Kesic, Radmila Obradovic, Sonja Mindova, Salvador Nares (2010) Dentinal hypersensitivity following scaling and root planing: comparison of low-level laser and topical fluoride treatment. 25(5), 647-650.

K Matsumoto, H Tomonari, H Wakabayashi (1985) Study on the treatment of hypersensitive dentine by laser. 28, 1366-1371.

C Aun, A Brugnera-Júnior, R Villa (1989) Raio laser-Hipersensibilidade dentinária. 43(2), 65-68.

M Yamaguchi, M Ito, T Miwata (1990) Clinical study on the treatment of hypersensitive dentin by GaAlAs laser diode using the double-blind test. 28(2), 703-707.

A Brugnera, F Zanin, A Pinheiro (2001) LLLT in treating dentinal hypersensibility: a histologic study and clinical application. 23-31.

César Arrais, Daniel Chan, Marcelo Giannini (2004) Effects of desensitizing agents on dentinal tubule occlusion. 12(2), 144-148.

J Wefel (2009) NovaMin®: Likely Clinical Success. 21(1), 40-43.

K Rajesh, S Hedge, Arun Kumar, M Shetty, D (2012) Evaluation of the efficacy of a 5% calcium sodium phosphosilicate (Novamin) containing dentifrice for the relief of dentinal hypersensitivity: a clinical study. 23, 363-367.

Q Du Min, Z Bian, H Jiang, D Greenspan, A Burwell, J Zhong (2008) Clinical evaluation of a dentifrice containing calcium sodium phosphosilicate (novamin) for the treatment of dentin hypersensitivity. 21, 210-214.

A De Assis Cde, R Antoniazzi, F Zanatta, C Rosing (2006) Efficacy of Gluma Desensitizer on dentin hypersensitivity in periodontally treated patients. 20, 252-256.

S Singh (2013) Pro-Argin: a breakthrough technology for dentin hypersensitivity treatment. 1, 133-137.

Comparitive Evaluation of Novel Desensitising Agents on Dentinal Tubule Occlusion-A Scanning Electron Microscopic Study

Published

2020-07-11

How to Cite

Comparitive Evaluation of Novel Desensitising Agents on Dentinal Tubule Occlusion-A Scanning Electron Microscopic Study. (2020). Global Journal of Medical Research, 20(J5), 11-16. https://medicalresearchjournal.org/index.php/GJMR/article/view/101397