Influence of Metallurgy and File Design in Micro Crack Formation in Root Canals - An in Vitro Study

Authors

  • Dr. Jyothilekshmi B

  • Dr. Rajesh Pillai

  • Dr. N O Varghese

  • Dr. Afzal Abdul Salim

  • Dr. Sheila George

  • Dr. Nikhil Murali

  • Dr. Geetha Ramachandran

Keywords:

cracks, controlled memory, dentinal damage, xp endo shaper, hyflex cm, hero shaper, max wire technology

Abstract

Abstract not found

How to Cite

Influence of Metallurgy and File Design in Micro Crack Formation in Root Canals - An in Vitro Study. (2020). Global Journal of Medical Research, 20(18), 1-6. https://medicalresearchjournal.org/index.php/GJMR/article/view/2031

URL: https://medicalresearchjournal.org/index.php/GJMR/article/view/2031

References

D. Shori, P. Shenoi, A. Baig, R. Kubde, C. Makade, S. Pandey (2015) Stereomicroscopic evaluation of dentinal defects induced by new rotary system: "ProTaper NEXT. 18, 210-213.

Ustun Y, Aslan T, Sagsen B, Kesim B (2015) The effects of different nickel-titanium instruments on dentinal microcrack formations during root canal preparation. 9, 41-46.

Peter Zahi Tawil, Elisa, Kristin Arnarsdottir1, Marcelo Santos, Coelho (2017) Root-originating dentinal defects: methodological aspects and clinical relevance. 2, 8.

Shemesh H, Bier CA, Wu MK, Tanomaru-Filho M, Wesselink PR (2009) The effects of canal preparation and filling on the incidence of dentinal defects. 42(3), 208-13.

Kesim B, Sagsen B, Aslan T (2017) Evaluation of dentinal defects during root canal preparation using thermomechanically processed nickel-titanium files. 11, 157-161.

J. Int (2015) Kumar SR,Gade V.Single file NiTi rotary Systems. 4(1), 701.

Azadeh a, Sina a, Mahgol b*, Elham a, Ali c (2017) Incidence of Dentinal Crack after Root Canal Preparation by ProTaper Universal, Neolix and Safe Sider Systems.IEJ Iranian Endodontic Journal 2017. 12(4), 432-438.

Kinjal Gathani (2018) Comparison of Dentinal Microcrack Formation during Root Canal Preparation by Niti Rotary Instruments and the Self- Adjusting File - An In Vitro Study. 2(6), 11-15.

Melike Bayram, Bayram (2017) Emre Bayram .Micro-computed Tomographic Evaluation of Dentinal Microcrack Formation after Using New Heat-treated Nickeltitanium Systems.

H. Bayram, Emre Bayram, Mert Ocak, Ahmet Uygun, Hakan Celik (2017) Effect of ProTaper Gold, Self-Adjusting File, and XP-endo Shaper Instruments on Dentinal Microcrack Formation: A Micro-computed Tomographic Study.

Wilcox LR, Roskelley C, Sutton T (1997) The relationship of root canal enlargement to finger-spreader induced vertical root fracture. 23, 533-534.

Sehnaz Oguz Yoldas, Gokhan Yilmaz, Cihan Atakan, Zeynep Kuden, Kasan (2012) Dentinal Microcrack Formation during Root Canal Preparations by Different NiTi Rotary Instruments and the Self-Adjusting File. 38, 232-235.

Kim HC, Lee MH, Yum J, Versluis A, Lee CJ, Kim BM (2010) Potential Relationship between Design of Nickel-Titanium Rotary Instruments and Vertical Root Fracture. 36, 1195-1199.

Pasqualini D, Scotti N, Tamagnone L, Ellena F, Berutti E (2008) Hand-operated and Rotary ProTaper Instruments: A Comparison of Working Time and Number of Rotations in Simulated Root Canals. 34, 314-317.

Bier CA, Shemesh H, Tanomaru-Filho M, Wesselink PR, Wu MK (2009) The Ability of Different Nickel-Titanium Rotary Instruments To Induce Dentinal Damage During Canal Preparation. 35, 236-238.

Ekta Garg, Shafia Sarfi, Dildeep Bali, Akhil Garg (2017) Comparative evaluation of dentinal defects induced by hand files, hyflex, protaper next and one shape during canal preparation: A stereomicroscopic study. 9(1), 16. https://doi.org/10.4103/2231-0754.201735

N. Madan, A. Rathnam, A. Shigli, K. Indushekar (2011) K-file vs ProFiles in cleaning capacity and instrumentation time in primary molar root canals: An in vitro study. 29(1), 2. https://doi.org/10.4103/0970-4388.79907

Chaudhary NR, Singh DJ, Somani R, Jaidka S (2018) Comparative Evaluation of Efficiency of Different File Systems in Terms of Remaining Dentin Thickness Using Cone-Beam Computed Tomography: An In vitro Study. 9, 367-371.

M. Veltri, A. Mollo, L. Mantovani, P. Pini, P. Balleri, S. Grandini (2005) A comparative study of Endoflare-Hero Shaper and Mtwo NiTi instruments in the preparation of curved root canals. 38(9), 610-6.

Gao Y, Gutmann JL, Wilkinson K, Maxwell R, Ammon D (2012) Evaluation of the Impact of Raw Materials on the Fatigue and Mechanical Properties of ProFile Vortex Rotary Instruments. 38(3), 398-401.

Testarelli L, Plotino G, Al-Sudani D (2011) Bending Properties of a New Nickel-Titanium Alloy with a Lower Percent by Weight of Nickel. 37(9), 1293-1295.

Adorno CG, Yoshioka T, Suda H (2009) The effect of root preparation technique and instrumentation length on the development of apical root cracks. 35, 389-92.

Anjali Rui Liu, Paul Hagay Shemesh (2013) Wesselink,Benxiang, Hou, Min-Kai Wu Incidence of Apical Root Cracks and Apical Dentinal Detachments after Canal Preparation with Hand and Rotary Files at Different Instrumentation Lengths. 39, 129-13.

G. Gambarini (2000) Rationale for the use of low‐torque endodontic motors in root canal instrumentation. 16(3), 95-100. https://doi.org/10.1034/j.1600-9657.2000.016003095.x

A. Tamse, Z. Fuss, J. Lustig, J. Kaplavi (1999) An evaluation of endodontically treated vertically fractured teeth. 25, 506-508.

Onnink PA, Davis RD, Wayman BE (1994) An in vitro comparison of incomplete root fractures associated with three obturation techniques. 20, 32-37.

Influence of Metallurgy and File Design in Micro Crack Formation in Root Canals - An in Vitro Study

Published

2020-03-30

How to Cite

Influence of Metallurgy and File Design in Micro Crack Formation in Root Canals - An in Vitro Study. (2020). Global Journal of Medical Research, 20(18), 1-6. https://medicalresearchjournal.org/index.php/GJMR/article/view/2031