Results of Hygiene Education of Kitchen Cutting Board by using ATP Inspection - Comparison of Vegetable Cutting Board and Meat Cutting Board

Authors

  • Naomi Katayama

  • Mayumi Hirabayashi

  • Akemi Ito

  • Shoko Kondo

  • Yui Nakayama

  • Ayari Naka

Keywords:

gender; ATP wiping test, Cutting board, Hygiene education, double wash

Abstract

Since bacteria grow in high temperature and high humidity, bacterial food poisoning frequently occurs from the rainy season to summer. In Japan, the number of food poisoning cases is high from June to October. Maintaining a hygienic environment in the kitchen is very important for preventing food poisoning. In particular, cutting boards on which various foods are places may cause secondary pollution. Therefore, to avoid food poisoning, this study compared the ATP value of the cutting board before and after the hygiene education using the ATP wiping test and investigated the educational effect. Before hygiene education, the inspector conducted an ATP wiping test on the cutting boards for vegetables and meat that washed before and after cooking and notified the cooks of the values. The inspector conducted hygiene education while showing the cook how to clean the cutting board. The cutting board washed with detergent and sponge, rinsed with running water for 30 seconds or more, then this process was repeated twice.

How to Cite

Results of Hygiene Education of Kitchen Cutting Board by using ATP Inspection - Comparison of Vegetable Cutting Board and Meat Cutting Board. (2020). Global Journal of Medical Research, 20(K5), 13-16. https://medicalresearchjournal.org/index.php/GJMR/article/view/2081

References

N Nante, E Ceriale, G Messina, D Lenzi, P Manzi (2017) Effectiveness of ATP bioluminescence to assess hospital cleaning: a review. 58(2), 177-E183.

E Amodio, C Dubi (2014) Use of ATP bioluminescence for assessing h eclealiness of hospital surfaces: a review of the published literature (1990-2012). 7(2), 92-98.

H Aycieck, U Oquz, K Karci (2006) Comparison of results of ATP bioluminescence and traditional ygiene swabbing methods for the deteminaton of surface cleanliness at a hospital kitchen. 209(2), 203-206.

Andrea Osimani, Cristiana Garofalo, Francesca Clementi, Stefano Tavoletti, Lucia Aquilanti (2014) Bioluminescence ATP Monitoring for the Routine Assessment of Food Contact Surface Cleanliness in a University Canteen. 11(10), 10824-10837.

Jee Lee (2018) An Investigation of Factors that Influence Hygiene Practices at a Small Day Care Center. 81(1), 158-164.

Philip Stanley (1989) A review of bioluminescent ATP techniques in rapid microbiology. 4(1), 375-380.

C Stannard, P Gibbs (1986) Rapid microbiology: Applications of bioluminescence in the food industry a review. 1(1), 3-10.

C Griffith, R Cooper, J Gilmore, C Davies, M Lewis (2000) An evaluation of hospital cleaning regimes and standards. 45(1), 19-28.

Results of Hygiene Education of Kitchen Cutting Board by using ATP Inspection - Comparison of Vegetable Cutting Board and Meat Cutting Board

Published

2020-05-28

How to Cite

Results of Hygiene Education of Kitchen Cutting Board by using ATP Inspection - Comparison of Vegetable Cutting Board and Meat Cutting Board. (2020). Global Journal of Medical Research, 20(K5), 13-16. https://medicalresearchjournal.org/index.php/GJMR/article/view/2081