Fundamental Study of Quantitative Evaluation of Radio Wave Output of Wireless Medical Telemetry Transmitters Operable in Medical Field

Authors

  • Kiyotaka Fujii

  • Kazumasa Kishimoto

  • Munenori Inoue

Keywords:

wireless medical telemetry transmitter, distance characteristics, free-space propagation model

Abstract

Wireless medical telemetry systems (WMTSs) are important medical equipment for monitoring of biological information such as the electrocardiogram of a patient in a remote location in real time. However, because WMTSs have characteristically used channels that are unique to the radio wave spectrum, many institutions have not previously managed WMTSs. Therefore, we examined a method for quantitative evaluation of the radio wave output of a wireless medical telemetry transmitter (WMTT) that can even be implemented in the medical field. In the experiments, we demonstrated the possibility of use of the method for quantitative evaluation of WMTT radio wave output in the medical field using two types of radio wave propagation model: a free-space propagation model and a two-ray ground reflection model. To determine the reference threshold value for use of each model, a breakpoint was found to be important to grasp the change point between short distance and long distance. It was indicated that the measured value was lower than the theoretical value below the breakpoint, while the measured value was slightly higher than the theoretical value beyond the breakpoint.

How to Cite

Fundamental Study of Quantitative Evaluation of Radio Wave Output of Wireless Medical Telemetry Transmitters Operable in Medical Field. (2020). Global Journal of Medical Research, 20(44), 5-10. https://medicalresearchjournal.org/index.php/GJMR/article/view/2178

URL: https://medicalresearchjournal.org/index.php/GJMR/article/view/2178

References

Ministry of Health, Labor, Welfare (2007) The fifth revision of the medical law.

Electromagnetic Japan (2016) Guidance for using a radio wave securely and safety in a hospital. http://www.emcc-info.net/info/info280404.html

E. Hanada, K.ishida, T.Kudou (2018) Newly identified electromagnetic problems with medical telemetry systems. 2, 21-24.

K. Ishida (2018) Electromagnetic compatibility of wireless medical telemetry systems and light-emitting diode (LED) lamps. 2, 25-28.

Fujii, Y. Ohno, M. Kido, K. Ishida, H. Jeong (2018) Effect of Wandering Sensing Systems on Wireless Medical Telemetry Systems. 38(6), 321-336.

S. Yamaguchi, M. Hayashi, T. Komatsu (2010) Transmission range of the wireless medical telemetry system and its dager. 80(5), 171-172.

Association of Radio Industries and Businesses (2008) Medical Telemeter Radio Equipment for Specified Low Power Radio Station.

Y. Karasawa Radiowave propagation fundamentals for digital mobile communications (second edition). 15-21.

J. Takada (2004) Basic theory of radio wave propagation. https://www.apmc-mwe.org/mwe2005/src/TL/TL05-01.pdf

Fundamental Study of Quantitative Evaluation of Radio Wave Output of Wireless Medical Telemetry Transmitters Operable in Medical Field

Published

2020-07-17

How to Cite

Fundamental Study of Quantitative Evaluation of Radio Wave Output of Wireless Medical Telemetry Transmitters Operable in Medical Field. (2020). Global Journal of Medical Research, 20(44), 5-10. https://medicalresearchjournal.org/index.php/GJMR/article/view/2178