Effect of Alcohol Disinfection on the Handle and Blade of Vegetables Knives by using ATP Inspection and Microbial Stamp Test
Keywords:
ATP test, microbial stamp test, the handle of the knife, the blade of the knife, alcohol disinfection
Abstract
To prevent food poisoning, we focused on kitchen vegetable knives, which are likely to cause secondary contamination, and conducted hygiene inspections to obtain results. The values after cooking and after washing, and after washing and after 70%spraying alcohol compared using the ATP wiping test and the microbial stamp test (selective medium: general bacteria, Escherichia coli, Staphylococcus aureus, Salmonella, Vibrio parahaemolyticus). As a result, the ATP test value decreased statistically significantly and became 100 or less after 70%alcohol sprayings. However, not all of the bacterial counts in the selective medium were statistically significantly different even after 70%alcohol sprayings. The reason the data was not clear due to 70% alcohol spray conditions. It may be advisable to perform a microbiological stamp test after applying 70%alcohol spray multiple times instead of once to a fully moistened knife handle and blade. In the future, we would like to consider the handling of more hygienic cooking utensils by further changing the 70%alcohol spraying conditions and conducting, Microbiological tests using a selective medium.
Downloads
- Article PDF
- TEI XML Kaleidoscope (download in zip)* (Beta by AI)
- Lens* NISO JATS XML (Beta by AI)
- HTML Kaleidoscope* (Beta by AI)
- DBK XML Kaleidoscope (download in zip)* (Beta by AI)
- LaTeX pdf Kaleidoscope* (Beta by AI)
- EPUB Kaleidoscope* (Beta by AI)
- MD Kaleidoscope* (Beta by AI)
- FO Kaleidoscope* (Beta by AI)
- BIB Kaleidoscope* (Beta by AI)
- LaTeX Kaleidoscope* (Beta by AI)
How to Cite
References
H Aycieck, U Oquz, K Karci (2006) Comparison of results of ATP bioluminescence and traditional ygiene swabbing methods fro the deteminaton of surface cleanliness at a hospital kitchen. 209(2), 203-206.
Andrea Osimani, Cristiana Garofalo, Francesca Clementi, Stefano Tavoletti, Lucia Aquilanti (2014) Bioluminescence ATP Monitoring for the Routine Assessment of Food Contact Surface Cleanliness in a University Canteen. 11(10), 10824-10837.
Jee Lee (2018) An Investigation of Factors that Influence Hygiene Practices at a Small Day Care Center. 81(1), 158-164.
C Griffith, R Cooper, J Gilmore, C Davies, M Lewis (2000) An evaluation of hospital cleaning regimes and standards. 45(1), 19-28.
C Stannard, P Gibbs (1986) Rapid microbiology: Applications of bioluminescence in the food industry a review. 1(1), 3-10.
N Nante, E Ceriale, G Messina, D Lenzi, P Manzi (2017) Effectiveness of ATP bioluminescence to assess hospital cleaning: a review. 58(2), 177-E183.
Emanuele Amodio, Claudia Dino (2014) Use of ATP bioluminescence for assessing the cleanliness of hospital surfaces: A review of the published literature (1990-2012). 7(2), 92-98.
Philip Stanley (1989) A review of bioluminescent ATP techniques in rapid microbiology. 4(1), 375-380.
Naomi Katayama, Akemi Ito, Mayumi Hirabayashi, Shoko Kondo, Yui Nakayama, Ayari Naka, Natuki Sasaki, Moe Inuzuka, Takashi Tamura (2020) Results of Hygiene Education of Kitchen Knife by using ATP Inspection - Comparison of Handle and Blade. 20(5), 1-6.
N Katayama, M Hirabayashi, A Ito, S Kondo, Y Nakayama, A Naka, N Sasaki, M Inuzuka, T Tamura (2020) Results of Hygiene Education of Kitchen Cutting Board by using ATP Inspection -Comparison of Vegetable Cutting Board and Meat Cutting Board. 20(5), 13-16.
Naomi Katayama, Shoko Kondo, Akemi Ito, Mayumi Hirabayashi, Yui Nakayama, Ayari Naka, Natuki Sasaki, Moe Inuzuka, Takashi Tamura (2020) Results of Hygiene Education of Kitchen Stove Knob and Water Faucet by using ATP Inspection. 20(5), 35-38.
Published
2020-11-11
Issue
Section
License
Copyright (c) 2020 Authors and Global Journals Private Limited

This work is licensed under a Creative Commons Attribution 4.0 International License.