Optimizing the Combination of Different Pulsed Nd:YAG Laser Beam Welding Process Parameters to Attain Minimum HAZ for Thin Cp.Ti With Ti-6Al-7Nb Sheets Using Response Surface Methodology(RSM) Method

Authors

  • Weaam Mohammed Moslim

Keywords:

Nd: YAG laser welding, Cp Ti alloy, Ti-6Al-7Nb alloy, Heat affected zone(HAZ), RSM Technique

Abstract

The objectives of this study were to test the effect of Nd: YAG Laser welding parameters (WP, PE, Ton and WS) on the HAZ of C.P Ti and T-6Al-7Nb alloys. The chosen Nd: YAG Laser welding parameters were three levels and CCD was selected to design the experiments. A 2nd regression equation relating to outputs and Nd: YAG Laser welding parameters was developed by using RSM. The result conducted that all the main effects of input parameters, i.e., WP, PE, Ton, and WS were found to be highly significant in affecting the HAZ.

How to Cite

Optimizing the Combination of Different Pulsed Nd:YAG Laser Beam Welding Process Parameters to Attain Minimum HAZ for Thin Cp.Ti With Ti-6Al-7Nb Sheets Using Response Surface Methodology(RSM) Method. (2021). Global Journal of Medical Research, 20(K14), 15-24. https://medicalresearchjournal.org/index.php/GJMR/article/view/2347

References

Hwk Luk, Ehn Pow, A Mcmillan, C Hui (2004) A double casting technique to minimize distortion 23 Year 2020 when constructing fixed partial dentures on implants. 91, 93-99.

T Kaus, L Probster, H Weber (1996) Clinical follow-up study of ceramic veneered titanium restorations-Three-year results. 15(77), 90.

Et Viritpon Srimaneepong (2005) Mechanical Strength and Microstructure of Laser-welded Ti-6Al-7Nb Alloy Castings. 24(4), 541-549.

T Jemt, P Henry, B Linden, I Naert, H Weber, C Bergstrom (2000) A comparison of laser welded titanium and conventional cast frameworks supported by implants in the partially edentulous jaw: a 3 year prospective multicenter study. 13, 282-288.

Masatoshi Ishikawa, Toshiya Kashiwabara, Osamu Ishida, Tetsuo Ichikawa (2002) Installing magnetic keepers using laser welding. 11(1), 49-52.

Ikuya Watanabe, Yasuhiro Tanaka, Chikahiro Ohkubo, Amp Miller (2002) Application of cast magnetic attachments to sectional complete dentures for a patient with microstomia: A clinical report. 88(6), 573-577.

Thomas Gordon, Denton Smith (1970) Laser welding of prostheses-an initial report. 24(4), 472-476.

Minamizat Rt (1974) Basic Study on Laser Welding of Dental Materials. 17(4), 524-529.

T Okabe, H Heror (1995) The user of titanium in dentist yr. 5, 211-230.

I Watanabe, J Watkins, H Nakajima, M Atsuta, T Okabe (1997) Effect of Pressure Difference on the Quality of Titanium Casting. 76(3), 773-779.

N Baba, I Watanabe (2004) Penetration depth into dental casting alloys by Nd:YAG laser. 72B(1), 64-68.

K Kleine, W Fox, K Watkins (2004) Micro Welding with Pulsed Single Mode Fiber Lasers.

Yasuhiro Okamoto, Arnold Gillner, Alexander Olowinsky, Jens Gedicke, Yoshiyuki Uno (2007) Fine micro-welding of thin metal sheet by high speed laser scanning. 6593, 65930D.

Tim Pasang, Yuan Tao, Mana Azizi, Osamu Kamiya, Masami Mizutani, Wojciech Misiolek (2017) Welding of titanium alloys. 123, 00001.

Z Abdalwahed, K Jadee1, H Rand Ameen (2019) Formability of laser welding plates of dissimilar materials. 518, 1-12.

E Akman, A Demir, T Canel, T Sınmazçelik (2009) Laser welding of Ti6Al4V titanium alloys. 209(8), 3705-3713.

Optimizing the Combination of Different Pulsed Nd:YAG Laser Beam Welding Process Parameters to Attain Minimum HAZ for Thin Cp.Ti With Ti-6Al-7Nb Sheets Using Response  Surface Methodology(RSM) Method

Published

2021-01-06

How to Cite

Optimizing the Combination of Different Pulsed Nd:YAG Laser Beam Welding Process Parameters to Attain Minimum HAZ for Thin Cp.Ti With Ti-6Al-7Nb Sheets Using Response Surface Methodology(RSM) Method. (2021). Global Journal of Medical Research, 20(K14), 15-24. https://medicalresearchjournal.org/index.php/GJMR/article/view/2347